Fast power. Lower cost. Smaller footprint.

Centralized String-Type Boost Integrated Cabin 35/5000

Built like a tank, thinks like a pro — an integrated 1500 V string-type PCS (2×2.5 MW) + dry-type transformer + MV switchgear package that drops in fast, stabilizes voltage, and keeps O&M effortless for enterprise users and community projects.

 

Compliance Standards: UN 38.3, UN 3551, UN3552, IEC 61000, IEC 62619, IEC 62477,IEC 60529,GB/T 36276

Key Features

Smart O&M

Remote monitoring and diagnostics, event alarms, trend analytics, and user-friendly dashboards to cut truck rolls and downtime.

Flexible string architecture

Compatible with multiple parallel battery strings; easy to scale or reconfigure as needs grow.

Efficient energy conversion

Precision charge/discharge control to boost battery utilization and lifecycle while minimizing losses in the PCS + MV stage.

Rapid deployment

Factory-assembled, function-tested MV skid reduces on-site wiring and shortens AC/DC integration time.

Highly integrated MV cabin

Converts, steps-up, distributes, and communicates in one enclosure—1500 V string-type PCS (2×2.5 MW) paired with a dry-type transformer and MV switchgear for a compact footprint and faster commissioning.

Stable 35 kV output

Ring-main–ready “hand-in-hand” (one-in/one-out) topology via vacuum circuit breaker and isolators for robust grid interconnection.

Built for safety & reliability

Core modules with high ingress protection (up to IP66 class for key components), coordinated electrical and fire protection, and ruggedized structure for harsh sites.

Site-agnostic design

Dry-type transformer simplifies permitting and indoor/urban use; wide environmental adaptability for hot/cold climates and corrosive coastal sites (C-class coatings available).

Technical Specifications

Control Topology Diagram Centralized,String-Type Boost Integrated Cabin 35 5000
Control Topology Diagram Centralized,String-Type Boost Integrated Cabin 35 5000
CategoryParameterSpecification
AC / Grid SideIsolation MethodTransformer isolation
 Rated Grid Voltage35 kV
 Rated Grid Frequency50/60 Hz
 Total Harmonic Distortion (THD)< 3%
 Power Factor Range−1 to +1
 Rated Apparent Capacity5,000 kVA
 Transformer TypeDry-type / Oil-immersed
 Transformer LV/MV Voltage0.69 / 35 kV
DC SideMaximum DC Bus Voltage1500 V
 DC Voltage Operating Range1000–1500 V
 Maximum DC Side Current2 × 2,584 A
 Number of DC Input Circuits4
 Branch Power × Quantity2,500 kW × 2
 Rated Power5,000 kW
 Maximum Output Power6,000 kW (1 min)
Environment & ProtectionAllowable Ambient Temperature−30 °C to +60 °C (derate above 45 °C)
 Allowable Relative Humidity100%
 Allowable Altitude< 5,000 m (derate above 3,000 m)
 Protection LevelIP54
CommunicationBMS Communication InterfaceRS485
 EMS Communication InterfaceEthernet
 ProtocolsModbus RTU, Modbus TCP, IEC 104, IEC 61850
Compliance & FunctionsCompliance StandardsGB/T 34120, GB/T 34133, GB/T 36547
 Grid/Control FunctionsHigh/Low Voltage Ride-Through, Grid Support, Frequency Regulation, Voltage Regulation, Network Configuration, etc.
String-Type Boost Integrated Cabin 35 5000
String-Type Boost Integrated Cabin 35 5000
CategoryItemSpecification
AC SideAC Connection MethodThree-Phase Three-Wire (Including Boost Transformer)
 Rated Power5000 kW
 Short-Term Overload110% (continuous)
 Overload Capacity120% (1 min)
 Rated Grid Voltage35 kV
 Rated Grid Frequency50 Hz / 60 Hz
 Frequency Range47–53 Hz / 57–63 Hz
 Total Current Distortion (THD)< 3%
 Power Factor> 0.99 (at >20% load)
 Adjustable Power Factor Range1 (Leading) – 1 (Lagging)
DC Side (Battery)Rated Power5500 kW (215 kW × 24)
 Maximum Continuous Operating Power5500 kW (215 kW × 1.1 × 24)
 Short-Term Overload Capacity (1 min)6000 kW (215 kW × 1.2 × 24)
 DC Voltage Range100–1500 V
 Maximum Long-Term Operating Current236 A × 24
 Voltage Ripple±2%
 Current Ripple±3%
SystemDimensions (L × W × H)8189 × 3200 × 3200 mm
 Protection LevelIP54
 Noise Level< 80 dB (at 1 m)
 Operating Ambient Temperature−40 ℃ to +60 ℃ (derating above 50 ℃)
 Storage Ambient Temperature−40 ℃ to +70 ℃
 Cooling MethodForced Air Cooling
 Allowable Relative Humidity0–95%, no condensation
 Communication InterfacesEthernet, RS485
 Control System DistributionSelf-powered method

Next steps

Ready to spec your 5 MW cabin? Choose your next step below and we’ll follow up fast.

  • Request the datasheet + SLD (single-line diagram) and I/O list.
  • Book a 15-minute engineering consult to review layouts, protections, and SCADA points.
  • Ask for an EPC-ready tender pack (technical spec, compliance matrix, FAT/SAT checklist).
  • Get a budgetary quote with lead time and delivery terms for your site conditions.